Understanding the Need for CT Replacement Tubes
Computed tomography systems rely on rotating anode X-ray tubes as their core imaging component, and these tubes are classified as wearing parts with a finite operational life. When a CT tube reaches the end of its service life or experiences failure, healthcare facilities face a critical decision: source an original equipment manufacturer replacement at high cost, or identify a compatible alternative that restores imaging capability without unnecessary downtime. Longcare Medical, a medical device manufacturer and exporter with multiple brand lines, addresses this exact pain point through its dedicated line of CT Tubes & Tube Assemblies, positioned specifically as replacement and OEM components for computed tomography equipment used in medical and physical examination institutions.
Why Tube Replacement Matters for Hospital Operations
CT downtime caused by tube failure directly affects diagnostic throughput, patient scheduling, and institutional revenue. High replacement cost for OEM tube assemblies compounds this operational pressure, particularly for secondary-level hospitals and physical examination centers operating on constrained budgets. Longcare Medical’s product line is built around solving two interconnected problems: minimizing the downtime caused by CT tube failure and reducing the high replacement cost typically associated with OEM tube assemblies. By offering compatible rotating anode X-ray tubes and complete tube assemblies, Longcare Medical gives imaging departments a practical path back to full operation.
A Comprehensive Lineup of Tube Inserts and Assemblies
Longcare Medical’s CT Tubes & Tube Assemblies category includes ten distinct products: RXT140, RXT190, RS350, RS500, RS600, RS800, RS35030, RS35035, RSA61, and RSL81. These products fall into two categories—standalone tube inserts (RXT140, RXT190) and complete tube assemblies that combine the insert with housing, stator, and cooling systems (RS350, RS500, RS600, RS800, RS35030, RS35035, RSA61, RSL81).

Tube Inserts: RXT140 and RXT190
The RXT140 is a 140 mm diameter target plate X-ray tube with 3.5 MHU heat content, built with a TZM-based W-Re alloy target and a 140 kV nominal tube voltage. It delivers nominal CT anode input power of 28 kW at 4.0 seconds and 34 kW at 4.0 seconds, with focal spot values of 0.8×0.4 and 0.8×0.7, an anode start speed of at least 8400 RPM, and a weight including assembly flange of 8.4 kg ± 0.5 kg. It is compatible for installation in the RS350 tube assembly and other compatible assemblies produced by the company.
The RXT190 offers a larger 190 mm diameter target plate with 5 MHU heat content, suited to higher-workload CT demands. It supports a nominal CT anode input power of 36 kW at 4.0 seconds and 50 kW at 4.0 seconds, focal spot values of 0.5×1.0 and 1.0×1.0, an anode start speed of at least 6000 RPM, and a weight including assembly flange of 17.1 kg ± 0.5 kg. This insert is compatible with the RS500 tube assembly.
Complete Tube Assemblies for Multiple CT Platforms
Longcare Medical’s complete tube assemblies are each engineered as replacements for specific OEM tube assembly models, making cross-brand CT maintenance more accessible:
The RS350 replaces DURA202 assemblies and is compatible with Siemens Somatom Emotion, Emotion Duo, Huan Yue Duo, Scope, Spirit, and Balance CT models. It uses the RXT140 tube insert, delivers up to 34 kW nominal CT anode input power at 4.0 seconds, and weighs 48.2 kg ± 0.5 kg without additional components.
The RS500 replaces CTR2150 assemblies and supports Philips MX16, United Imaging uCT510/530/550, ScintCare16, Insitum16, and NeuViz16/16E/16pro, ANATOM 16 CT models. Built around the RXT190 insert, it reaches 50 kW nominal CT anode input power at 4.0 seconds and features an extraordinary cooling and ultrahigh heat capacity design.
The RS600 replaces MX200 / DA200 assemblies for GE OPTIMA CT660 and GE LightSpeed Zx/iNx/lQx/16 systems, using the RXT200 insert with a 200 mm diameter target plate, 6.3 MHU heat content, and up to 53 kW nominal CT anode input power.
The RS800 replaces CTR2280 assemblies for Neusoft NeuViz 128, NeuViz 64i, and Sinovision Insitum 64 systems. With an 8.0 MHU heat content RXT19064 insert and 80 kW nominal CT anode input power, it is engineered with Φ- and Z-deflection design for high-spec 64/128-slice CT platforms.
The RS35030 replaces GS307 series assemblies for Sinovision InsitumCT 338/318 and MinFound Scintcare blue 755 systems, offering rapid cooling and reduced vibration. The RS35035 replaces CTR1720/25/35/40 assemblies for Philips Access 16/MX4000/Access Dual and Neusoft NeuViz 16 Classic/Dual/Twin, emphasizing sharp image and low-noise performance.
The RSA61 replaces CHRONON assemblies for Siemens Somatom go.Now and go.Up systems with φ-deflection and high-definition image design, while the RSL81 replaces DURA422/688 assemblies for Siemens Somatom Emotion 6/16 and Somatom Perspective, featuring rapid cooling and low-noise construction.
Component Construction and Supply Model
Across the assembly lineup, Longcare Medical applies consistent engineering principles: housing, tube insert, stator, and insulation oil construction, with select models incorporating dedicated cooling units. These assemblies are supplied as components for X-ray tube replacement and OEM projects, meaning healthcare institutions can source them either as direct replacements for aging tubes or as part of broader equipment manufacturing partnerships.
Positioning Within a Broader Medical Imaging Portfolio
The CT Tubes & Tube Assemblies line sits within Longcare Medical’s wider capability system, which includes CT scanners, DSA/Cath-Lab systems, endoscopy equipment, MRI systems, ultrasound systems, and X-ray systems—all supported by quality frameworks such as NMPA China Medical Device Registration, ISO13485 Medical Quality Management System certification, and CE Certificate compliance where applicable. For medical and physical examination institutions seeking a dependable, cost-effective path to restoring CT functionality, Longcare Medical’s dedicated tube and tube assembly lineup offers a structured, model-specific solution designed around real-world replacement needs.

www.njlongcaremed.com
Nanjing Longcare Medical Equipment Co., Ltd.